Stone Processing Machinery

Flame Gas Acrylic Edage Sheet Polishing Machine

Jinan Finework CNC Machinery Co., Ltd.
  • After-sales Service:1year Free Tech Consult Acrylic Polishing Machine
  • Warranty:1year Flame Acrylic Polishing Machine
  • Type:Flame Acrylic Polishing Machine
  • Control:Artificial
  • Automation:Semi-automatic
  • Precision:Normal Precision

Base Info

  • Model NO.:flame acrylic polishing machine
  • Application:Acrylic Polishing Machine
  • Type for Grinding Machine:Flame Polishing Machine
  • Grinding Machine Type:Flame Polishing Machine
  • Grinding Method:Flame Polishing Machine
  • Certification:CE
  • Condition:New
  • Function:Plexiglass Acrylic Edge Polishing Machine
  • Applicate:Acrylic Flame Polishing Machine
  • Material:Flame Polishing Machine for Acrylic
  • Control System:Manual Flame Polishing Machine
  • Transport Package:Cartoon Box
  • Specification:480*280*360mm^3
  • Trademark:FINEWORKCNC acrylic polisher
  • Origin:China Acrylic Polishing Machine
  • HS Code:8208900000
  • Production Capacity:1000

Description

Overview Product Description

Detailed Photos

 

Flame Gas Acrylic Edage Sheet Polishing MachineFlame Gas Acrylic Edage Sheet Polishing MachineProduct Parameters

 

FAQ

flame yellow: too much filter, fire mouth is too dirty.

--Pour out excess detergent, clean the fire mouth and thoroughly poke the mouth of the fire with a small needle.

 

The barometer has air pressure but it does not vent

- There is a problem with the muzzle or gun body, the safety valve in the alcohol tank is blocked, replace the grab nozzle, repair the gun body, or replace and unscrew the alcohol can, clean the safety valve

 

 boot without any response: the insurance tube is broken

- Replacement of new fuses

 

Insufficient pressure: gas leakage, low current value

- Start with soapy water from the tip of the gun to find leakage points; replace the electrolyte

  There is no air current: polisher leak, pressure gauge damage

- check leak point; replace pressure gauge

 No current and no air pressure: circuit failure, pressure switch is broken

- Use a multimeter to check the cause step by step; Short-circuit pressure switch line, test machine is normal, if normal, replace the pressure switch, and adjust to make the maximum pressure does not exceed 0.1mp

tempering (a bang when the gun fire is turned off): failure of anti-tempering device, leakage of polisher

- Replacement of fire protection device; check leakage point

 

The acrylic that is thrown has bubbles, not shiny: Acrylic is not clean

- Clean Acrylic Materials

Attention :

Electrolyte: It must be filled for the first time. Strong alkaline 15-20% concentration.

Consumed fuel: water (distilled water, pure water, cold water, tap water)

Filter: Alcohol or distilled water with a purity above 95

Working environment: 0 °C ~ 50 °C, well-ventilated or air-conditioned environment